Terry <[EMAIL PROTECTED]> writes:

> Ive had a problem, and figured out a (bad..) workaround with the software 
> manager.
> 
> The problem was it was getting mixed up over my 2 cdroms (1 dvd, 1 cdrw).
> When trying to install a package, it would eject the dvdrom, (/mnt/cdrom), yet 
> the popup message would be saying put the disk in /mnt/cdrom2 which is the 
> cdrw.
> Ignoring the dvdrom and putting the disc in the cdrw did not help as it was 
> still looking at the dvdrom, but would not see any disc in the drive.....
> 
> For some reason the software manager had its links between /dev/hdc (the 
> dvdrom) and /mnt/cdrom2 (the cdrw) mixed up. Trying to edit the software 
> sources didnt help either, they are pointing at 
> removable://mnt/cdrom/Mandrake/RPMS, so im confused as to where cdrom2 gets 
> picked up from.....
> 
> In the end, i've added this to fstab none /mnt/cdrom2 supermount 
> dev=/dev/hdc,fs=auto,ro,--,iocharset=iso8859-15,codepage=850,umask=0 0 0 and 
> am now pointing the cdrw at /mnt/cdrom3

Francois, any idea?

-- 
Guillaume Cottenceau - http://people.mandrakesoft.com/~gc/

Reply via email to