On Fri, Oct 3, 2025 at 5:40 PM Undescribed Horrific Abuse, One Victim & Survivor of Many <[email protected]> wrote:
> Information on page 4 > > Table 1 Basic Operating Table is at the top, with a 2-paragraph caption. > > The bottom begins 1. Monostable Operation and has 3 figures. > > Figure 1 is a circuit diagram. Discharge 7 is wired to threshold 8 with a > resistor to VCc and a capacitor to ground. Cont 5 has a capacitor to > ground. 2 Trigger is wired to a user source, as is 3 out to a user load. > > Figure 2 shows R and C vs time. All lines are directly proportional to > time, at 45 degrees. It looks like C(t) = 0 moves to higher t values as the > resistance increases, crossing t=0 at R= 10kOhm I think. > > Figure 3 shows the waveforms of trigger, output, and threshold for > monostable operation, under R=9.1kOhm, load=1kOhm, C to thresh=0.01uF, > VCC=5v > > Output is a square wave. Thresh is a shark tooth while output=1, 0 when > output=0. Trigger is mostly high, 0 briefly at the start of the shark tooth. > Top of page 5: Figure 1 illustrates a monostable circuit. In this modem the timer generates a fixed pulse… :)