On Sat, May 24, 2008 at 03:23:14PM +0200, Yves-Alexis Perez wrote:
> Which version are you running?

2.6.25-2-686, which appears to be the most recent linux-image in Sid.
 
> Can you ls -Rl /sys/class/power_supply ?

$ ls -Rl /sys/class/power_supply
/sys/class/power_supply:
total 0
drwxr-xr-x 3 root root 0 2008-05-24 16:06 AC
drwxr-xr-x 3 root root 0 2008-05-24 15:08 BAT0

/sys/class/power_supply/AC:
total 0
lrwxrwxrwx 1 root root    0 2008-05-24 16:06 device -> 
../../../devices/LNXSYSTM:00/device:00/PNP0A03:00/device:01/PNP0C09:00/ACPI0003:00
-r--r--r-- 1 root root 4096 2008-05-24 16:06 online
drwxr-xr-x 2 root root    0 2008-05-24 16:06 power
lrwxrwxrwx 1 root root    0 2008-05-24 16:06 subsystem -> ../../power_supply
-r--r--r-- 1 root root 4096 2008-05-24 16:06 type
-rw-r--r-- 1 root root 4096 2008-05-24 16:06 uevent

/sys/class/power_supply/AC/power:
total 0
-rw-r--r-- 1 root root 4096 2008-05-24 16:06 wakeup

/sys/class/power_supply/BAT0:
total 0
-rw-r--r-- 1 root root 4096 2008-05-24 16:06 alarm
-r--r--r-- 1 root root 4096 2008-05-24 15:08 current_now
lrwxrwxrwx 1 root root    0 2008-05-24 16:06 device -> 
../../../devices/LNXSYSTM:00/device:00/PNP0A03:00/device:01/PNP0C09:00/PNP0C0A:00
-r--r--r-- 1 root root 4096 2008-05-24 15:08 energy_full
-r--r--r-- 1 root root 4096 2008-05-24 16:06 energy_full_design
-r--r--r-- 1 root root 4096 2008-05-24 15:08 energy_now
-r--r--r-- 1 root root 4096 2008-05-24 16:06 manufacturer
-r--r--r-- 1 root root 4096 2008-05-24 16:06 model_name
drwxr-xr-x 2 root root    0 2008-05-24 16:06 power
-r--r--r-- 1 root root 4096 2008-05-24 15:08 present
-r--r--r-- 1 root root 4096 2008-05-24 16:06 serial_number
-r--r--r-- 1 root root 4096 2008-05-24 15:08 status
lrwxrwxrwx 1 root root    0 2008-05-24 16:06 subsystem -> ../../power_supply
-r--r--r-- 1 root root 4096 2008-05-24 16:06 technology
-r--r--r-- 1 root root 4096 2008-05-24 16:06 type
-rw-r--r-- 1 root root 4096 2008-05-24 16:06 uevent
-r--r--r-- 1 root root 4096 2008-05-24 16:06 voltage_min_design
-r--r--r-- 1 root root 4096 2008-05-24 15:08 voltage_now

/sys/class/power_supply/BAT0/power:
total 0
-rw-r--r-- 1 root root 4096 2008-05-24 16:06 wakeup

The system in question is an IBM Thinkpad X31, with a single battery, on
power but not in the docking station. thinkpad_acpi module is loaded.

Bertram
-- 
Bertram Bourdrez <[EMAIL PROTECTED]>



-- 
To UNSUBSCRIBE, email to [EMAIL PROTECTED]
with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]

Reply via email to