On the E250, the "General Error" LED on the front status panel is plumbed to the auxio power LED bit (logical OR, if I recall correctly). If it bothers you, I'd be happy to provide a patch to you. Alternatively, I have a rough SUNW,envctrtltwo environmental monitoring driver for the E250 I'd be happy to provide-- I've been meaning to convert it to the in-kernel I2C subsystem and add multi-master support but I've just not gotten around to it. Let me know.
E On Mon, 1 Nov 2004 22:14:48 -0500, Huston <[EMAIL PROTECTED]> wrote: > > I have an E250 server. Every time it kicks in the hard drives. I get a > maintenance light. If I don't boot into the OS, I don't get the light. I > don't remember it doing this with Solaris. Is there something I need to > change configuration wise or did the problem just seem to coincide the > change of OS? The only thing I notice is the cdrom seems to show activity > longer.. Any suggestions would be appreciated..... -- E