> -----Original Message-----
> From: Thomas Monjalon <[email protected]>
> Sent: Monday, February 06, 2023 3:23 PM
> To: Mingjin Ye <[email protected]>
> Cc: [email protected]; [email protected]; [email protected]; Qiming Yang
> <[email protected]>; Qi Zhang <[email protected]>; Mingjin Ye
> <[email protected]>; [email protected];
> [email protected]
> Subject: Re: [PATCH] net/ice: fix get link status timeout
> 
> 06/02/2023 07:22, Mingjin Ye:
> > When hw is just started, it will immediately obtain the link status,
> > and the longest attempt is 1 second. Some NICs are slow to initialize,
> > which make it fails to obtain the link status.
> >
> > The patch fixes this issue by modifying the longest attempt to 5 seconds.
> 
> What is the consequence?
> In which case, DPDK application would be blocked during 5 seconds?
> 

I think ice_link_update with wait_to_complete needs to be optimized when 
ice_link_update.
Our system integrates dozens or more interfaces(E810), even if wait 1 second, 
the system starts very slowly.

Reply via email to