https://issues.apache.org/jira/browse/HTTPCLIENT-1770?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Julian Sedding updated HTTPCLIENT-1770:
---------------------------------------
Attachment: HTTPCLIENT-1770-jsedding.patch
Attached patch fixes the issue.
> [OSGi] metatype for org.apache.http.proxyconfigurator missing factoryPid
> ------------------------------------------------------------------------
>
> Key: HTTPCLIENT-1770
> URL: https://issues.apache.org/jira/browse/HTTPCLIENT-1770
> Project: HttpComponents HttpClient
> Issue Type: Bug
> Components: HttpClient (classic)
> Affects Versions: 4.5.2, 5.0 Alpha1
> Reporter: Julian Sedding
> Priority: Minor
> Labels: osgi
> Attachments: HTTPCLIENT-1770-jsedding.patch
>
>
> The metatype definition for {{org.apache.http.proxyconfigurator}} only lists
> the {{pid}} attribute on the {{Designate}} element. As it is a
> {{ManagedServiceFactory}} supporting multiple proxy configurations, the
> metatype should include a {{factoryPid}} attribute.
> E.g. in the Felix webconsole's configuration screen, there are currently two
> entries, one for a singleton component configuration and one for a factory
> configuration. This is confusing for users, especially since the singleton
> configuration does not work.
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)
---------------------------------------------------------------------
To unsubscribe, e-mail: [email protected]