https://issues.apache.org/jira/browse/JENA-1080?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15056130#comment-15056130
 ] 

Donald Pellegrino commented on JENA-1080:
-----------------------------------------

In my test environment, Internet Explorer 11 Developer Tools reports that 
Document mode 7 is "Via intranet compatibility settings." Microsoft's documents 
this behavior at "Emulate browsers, screen sizes, and GPS locations" 
(https://msdn.microsoft.com/library/dn255001(v=vs.85).aspx). The documentation 
reports the "Via intranet compatibility settings" applies when "The 'Display 
intranet sites in Compatibility View' box is checked in the Compatibility View 
settings." Therefore, this issue appears to be specific to the case of running 
IE11 in combination with hosting the Fuseki web site within an intranet having 
"Display intranet sites in Compatibility View." I need to investigate this 
further to see if it is possible to get Fuskei web pages rendered in "Edge" 
mode in environments where "Display intranet sites in Compatibility View" is 
set.

> Fuseki Web Interface incompatible with Internet Explorer
> --------------------------------------------------------
>
>                 Key: JENA-1080
>                 URL: https://issues.apache.org/jira/browse/JENA-1080
>             Project: Apache Jena
>          Issue Type: Improvement
>          Components: Fuseki
>    Affects Versions: Fuseki 2.3.0
>         Environment: Microsoft Internet Explorer 11.0.9600.18097
>            Reporter: Donald Pellegrino
>            Priority: Trivial
>              Labels: windows
>
> Microsoft Internet Explorer 11 defaults to rendering Apache Jena Fuseki web 
> pages in "Document mode 7." Using F12 and manually changing the "Document 
> mode" to "Edge" seems to work-around the problem.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to