Dan Burkert has submitted this change and it was merged.

Change subject: Change row projector schema equality check to use physical 
column type
......................................................................


Change row projector schema equality check to use physical column type

The row projector uses the column's physical type (e.g. for TIMESTAMP the
physical type is INT64) to build codegen cache keys, but used the normal column
type when comparing the projection schemas retrieved from the cache. This
resulted in spurious debug check failures.

Change-Id: I5e9a8d9c003be3942d3ce6f93d880adb45d8ded6
Reviewed-on: http://gerrit.cloudera.org:8080/2672
Reviewed-by: Todd Lipcon <[email protected]>
Tested-by: Kudu Jenkins
---
M src/kudu/codegen/row_projector.cc
M src/kudu/common/schema.h
2 files changed, 8 insertions(+), 3 deletions(-)

Approvals:
  Todd Lipcon: Looks good to me, approved
  Kudu Jenkins: Verified



-- 
To view, visit http://gerrit.cloudera.org:8080/2672
To unsubscribe, visit http://gerrit.cloudera.org:8080/settings

Gerrit-MessageType: merged
Gerrit-Change-Id: I5e9a8d9c003be3942d3ce6f93d880adb45d8ded6
Gerrit-PatchSet: 5
Gerrit-Project: kudu
Gerrit-Branch: master
Gerrit-Owner: Dan Burkert <[email protected]>
Gerrit-Reviewer: Adar Dembo <[email protected]>
Gerrit-Reviewer: Dan Burkert <[email protected]>
Gerrit-Reviewer: Jean-Daniel Cryans
Gerrit-Reviewer: Kudu Jenkins
Gerrit-Reviewer: Todd Lipcon <[email protected]>