https://issues.apache.org/jira/browse/LUCENE-3681?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=13182278#comment-13182278
]
Michael McCandless commented on LUCENE-3681:
--------------------------------------------
I like the idea of moving read/writeLabel to BytesReader/Writer and then
specializing...
> FST.BYTE2 should save as fixed 2 byte not as vInt
> -------------------------------------------------
>
> Key: LUCENE-3681
> URL: https://issues.apache.org/jira/browse/LUCENE-3681
> Project: Lucene - Java
> Issue Type: Improvement
> Reporter: Michael McCandless
> Assignee: Michael McCandless
> Fix For: 3.6, 4.0
>
> Attachments: LUCENE-3681.patch
>
>
> We currently write BYTE1 as a single byte, but BYTE2/4 as vInt, but I think
> that's confusing. Also, for the FST for the new Kuromoji analyzer
> (LUCENE-3305), writing as 2 bytes instead shrank the FST and ran faster,
> presumably because more values were >= 16384 than were < 128.
> Separately the whole INPUT_TYPE is very confusing... really all it's doing is
> "declaring" the allowed range of the characters of the input alphabet, and
> then the only thing that uses that is the write/readLabel methods (well and
> some confusing sugar methods in Builder!). Not sure how to fix that yet...
> It's a simple change but it changes the FST binary format so any users w/
> FSTs out there will have to rebuild (FST is marked experimental...).
--
This message is automatically generated by JIRA.