https://issues.apache.org/jira/browse/PARQUET-2222?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17747306#comment-17747306
 ] 

Antoine Pitrou commented on PARQUET-2222:
-----------------------------------------

bq. Should we just keep the specs as is and let the implementations decide 
which encoding to use for boolean values?

Makes sense. But can you please open an issue for these discussions? This is 
unrelated to the issue I originally reported, and which is fixed.

> [Format] RLE encoding spec incorrect for v2 data pages
> ------------------------------------------------------
>
>                 Key: PARQUET-2222
>                 URL: https://issues.apache.org/jira/browse/PARQUET-2222
>             Project: Parquet
>          Issue Type: Bug
>          Components: parquet-format
>            Reporter: Antoine Pitrou
>            Assignee: Xuwei Fu
>            Priority: Critical
>             Fix For: format-2.10.0
>
>
> The spec 
> (https://github.com/apache/parquet-format/blob/master/Encodings.md#run-length-encoding--bit-packing-hybrid-rle--3)
>  has this:
> {code}
> rle-bit-packed-hybrid: <length> <encoded-data>
> length := length of the <encoded-data> in bytes stored as 4 bytes little 
> endian (unsigned int32)
> {code}
> But the length is actually prepended only in v1 data pages, not in v2 data 
> pages.



--
This message was sent by Atlassian Jira
(v8.20.10#820010)