https://issues.apache.org/jira/browse/SLING-5914?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Carsten Ziegeler updated SLING-5914:
------------------------------------
    Fix Version/s:     (was: Sling Provisioning Model 1.8.2)
                   Sling Provisioning Model 1.8.4

> Provisioning model does not correctly handle floating-point configuration 
> values
> --------------------------------------------------------------------------------
>
>                 Key: SLING-5914
>                 URL: https://issues.apache.org/jira/browse/SLING-5914
>             Project: Sling
>          Issue Type: Bug
>          Components: Tooling
>            Reporter: Robert Munteanu
>             Fix For: Sling Provisioning Model 1.8.4
>
>
> The provisioning model specifies that floating-point values are encoded in 
> the following format:
> - {{D"1.0"}} for doubles
> - {{F"1.0"}} for floats
> However, the ConfigAdmin has a different idea about how these values should 
> be stored:
> {code:java}
>             case TOKEN_SIMPLE_FLOAT:
>             case TOKEN_PRIMITIVE_FLOAT:
>                 int fBits = Integer.parseInt( readQuoted( pr ) );
>                 return new Float( Float.intBitsToFloat( fBits ) );
>             case TOKEN_SIMPLE_DOUBLE:
>             case TOKEN_PRIMITIVE_DOUBLE:
>                 long dBits = Long.parseLong( readQuoted( pr ) );
>                 return new Double( Double.longBitsToDouble( dBits ) );
> {code}
> I assume that this is done to preserve precision when reading/writing values.
> The provisioning model should be updated to mediate between the user-supplied 
> values and the configuration admin format.



--
This message was sent by Atlassian JIRA
(v6.3.15#6346)

Reply via email to