[ https://issues.apache.org/jira/browse/SLING-5914?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel ]
Tomek Rękawek updated SLING-5914: --------------------------------- Fix Version/s: (was: Sling Provisioning Model 1.8.4) Sling Provisioning Model 1.8.6 > Provisioning model does not correctly handle floating-point configuration > values > -------------------------------------------------------------------------------- > > Key: SLING-5914 > URL: https://issues.apache.org/jira/browse/SLING-5914 > Project: Sling > Issue Type: Bug > Components: Tooling > Reporter: Robert Munteanu > Fix For: Sling Provisioning Model 1.8.6 > > > The provisioning model specifies that floating-point values are encoded in > the following format: > - {{D"1.0"}} for doubles > - {{F"1.0"}} for floats > However, the ConfigAdmin has a different idea about how these values should > be stored: > {code:java} > case TOKEN_SIMPLE_FLOAT: > case TOKEN_PRIMITIVE_FLOAT: > int fBits = Integer.parseInt( readQuoted( pr ) ); > return new Float( Float.intBitsToFloat( fBits ) ); > case TOKEN_SIMPLE_DOUBLE: > case TOKEN_PRIMITIVE_DOUBLE: > long dBits = Long.parseLong( readQuoted( pr ) ); > return new Double( Double.longBitsToDouble( dBits ) ); > {code} > I assume that this is done to preserve precision when reading/writing values. > The provisioning model should be updated to mediate between the user-supplied > values and the configuration admin format. -- This message was sent by Atlassian JIRA (v6.4.14#64029)