Hi Reka,

On Sun, Dec 21, 2014 at 1:18 PM, Reka Thirunavukkarasu <r...@wso2.com>
wrote:

> Hi Lahiru,
>
> I saw the following code when calculating required instances. Since it is
> checking the instanceRange > 0, whenever the cluster instance reaches it
> maximum, this instanceRange is 0.
>

We get the instance range from "max = min". If we remove this check, it may
divide a value from Zero, which will cause infinity(a very large value) in
Java.

So IMO we should handle the the "max = min" case in drools file separately.
We can send the max out event if predicted value is higher than threshold
in this case. I will implement it.

Thanks.

> At that point even though the load is high no decision is taken as the
> required instances is not getting calculated. Also, it is not notifying the
> parent as well even though it is max out.
>
> Shall we remove this check which will help to predict the required
> instances even when the max is reached. So that we can notify the parent
> about the max out.
>
> Thanks,
> Reka
>
> --
> Reka Thirunavukkarasu
> Senior Software Engineer,
> WSO2, Inc.:http://wso2.com,
> Mobile: +94776442007
>
>
>


-- 
--
Lahiru Sandaruwan
Committer and PMC member, Apache Stratos,
Senior Software Engineer,
WSO2 Inc., http://wso2.com
lean.enterprise.middleware

email: lahi...@wso2.com blog: http://lahiruwrites.blogspot.com/
linked-in: http://lk.linkedin.com/pub/lahiru-sandaruwan/16/153/146