In other words, window length is 10 minutes, but sliding interval is 1
minute.

On Tue, Jun 16, 2015 at 10:26 AM, Rajkumar Rajaratnam <rajkum...@wso2.com>
wrote:

> Hi Reka,
>
> I guess we are increasing window time interval to 10 minutes. But we will
> be sliding the window every minute. So CEP will publish events every 1
> minute. Isn't it Lahiru?
>
> Thanks.
>
> On Tue, Jun 16, 2015 at 10:20 AM, Reka Thirunavukkarasu <r...@wso2.com>
> wrote:
>
>> Hi Lahiru/Pranavan,
>>
>> If the CEP window interval changes to 10 min, then i hope that the
>> decision from CEP will be received by Autoscaler also in 10 min interval.
>> In that case, how will the prediction work? Are we predicting the load also
>> before 10 minutes? If the prediction time is less than 10 minutes, then we
>> might not have enough events in autoscaler to predict at some point? WDYT?
>>
>> Thanks,
>> Reka
>>
>> On Mon, Jun 15, 2015 at 11:30 PM, Pranavan Theivendiram <
>> pranavan...@cse.mrt.ac.lk> wrote:
>>
>>> Thanks for the update Lahiru. I will proceed with that time interval.
>>>
>>> *T. Pranavan*
>>> *BSc Eng Undergraduate| Department of Computer Science & Engineering
>>> ,University of Moratuwa*
>>> *Mobile| *0775136836
>>>
>>> On 15 June 2015 at 23:27, Lahiru Sandaruwan <lahi...@wso2.com> wrote:
>>>
>>>> Yes, we receive health stat publisher in cartridge agent sends events
>>>> in each 15 seconds. Therefore we will receive about 40 events in 10 mins.
>>>>
>>>> This is a good number to find the curve.
>>>>
>>>> Thanks.
>>>>
>>>> On Mon, Jun 15, 2015 at 11:20 PM, Pranavan Theivendiram <
>>>> pranavan...@cse.mrt.ac.lk> wrote:
>>>>
>>>>> Hi Lahiru,
>>>>>
>>>>> I am working on EMA implementation for the events coming from cep. If
>>>>> we take window interval of one minute, I will be receiving less number of
>>>>> events. If we change it to 10 minutes, we can receive more events. Then 
>>>>> the
>>>>> prediction will be more accurate. Shall we proceed with that?
>>>>>
>>>>> Thanks
>>>>>
>>>>> *T. Pranavan*
>>>>> *BSc Eng Undergraduate| Department of Computer Science & Engineering
>>>>> ,University of Moratuwa*
>>>>> *Mobile| *0775136836
>>>>>
>>>>> On 12 June 2015 at 16:59, Lahiru Sandaruwan <lahi...@wso2.com> wrote:
>>>>>
>>>>>> Hi Pranavan,
>>>>>>
>>>>>> Could you please send the background information of the decision.
>>>>>>
>>>>>> Thanks.
>>>>>>
>>>>>> On Fri, Jun 12, 2015 at 4:09 PM, Pranavan Theivendiram <
>>>>>> pranavan...@cse.mrt.ac.lk> wrote:
>>>>>>
>>>>>>> Hi All,
>>>>>>>
>>>>>>> Currently we are using 1 minute as the window interval time. Shall
>>>>>>> we change it to 10 minutes?
>>>>>>>
>>>>>>> Thanks
>>>>>>> *T. Pranavan*
>>>>>>> *BSc Eng Undergraduate| Department of Computer Science & Engineering
>>>>>>> ,University of Moratuwa*
>>>>>>> *Mobile| *0775136836
>>>>>>>
>>>>>>
>>>>>>
>>>>>>
>>>>>> --
>>>>>> --
>>>>>> Lahiru Sandaruwan
>>>>>> Committer and PMC member, Apache Stratos,
>>>>>> Senior Software Engineer,
>>>>>> WSO2 Inc., http://wso2.com
>>>>>> lean.enterprise.middleware
>>>>>>
>>>>>> phone: +94773325954
>>>>>> email: lahi...@wso2.com blog: http://lahiruwrites.blogspot.com/
>>>>>> linked-in: http://lk.linkedin.com/pub/lahiru-sandaruwan/16/153/146
>>>>>>
>>>>>>
>>>>>
>>>>
>>>>
>>>> --
>>>> --
>>>> Lahiru Sandaruwan
>>>> Committer and PMC member, Apache Stratos,
>>>> Senior Software Engineer,
>>>> WSO2 Inc., http://wso2.com
>>>> lean.enterprise.middleware
>>>>
>>>> phone: +94773325954
>>>> email: lahi...@wso2.com blog: http://lahiruwrites.blogspot.com/
>>>> linked-in: http://lk.linkedin.com/pub/lahiru-sandaruwan/16/153/146
>>>>
>>>>
>>>
>>
>>
>> --
>> Reka Thirunavukkarasu
>> Senior Software Engineer,
>> WSO2, Inc.:http://wso2.com,
>> Mobile: +94776442007
>>
>>
>>
>
>
> --
> Rajkumar Rajaratnam
> Committer & PMC Member, Apache Stratos
> Software Engineer, WSO2
>
> Mobile : +94777568639
> Blog : rajkumarr.com
>



-- 
Rajkumar Rajaratnam
Committer & PMC Member, Apache Stratos
Software Engineer, WSO2

Mobile : +94777568639
Blog : rajkumarr.com

Reply via email to