https://issues.apache.org/jira/browse/STRATOS-1615?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15004014#comment-15004014
]
Rajkumar Rajaratnam commented on STRATOS-1615:
----------------------------------------------
Fixed in 5c63e93026c580b373dbb513c1ae1c
> Monitors are not created on Stratos restart
> -------------------------------------------
>
> Key: STRATOS-1615
> URL: https://issues.apache.org/jira/browse/STRATOS-1615
> Project: Stratos
> Issue Type: Bug
> Components: Autoscaler
> Affects Versions: 4.1.4
> Reporter: Rajkumar Rajaratnam
> Assignee: Rajkumar Rajaratnam
> Priority: Blocker
> Fix For: 4.1.5
>
>
> Root cause is, AS received the complete-topology-event before loading
> application-contexts from registry to in-memory model. So the
> complete-topology-event is ignored by AS, but the topology is initialized.
> This also means that all the upcoming periodic complete-topology-events will
> be ignored by AS.
> This should be fixed by starting event receiver threads after loading
> policies/contexts from registry.
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)