https://issues.apache.org/jira/browse/STRATOS-1615?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Rajkumar Rajaratnam resolved STRATOS-1615.
------------------------------------------
    Resolution: Fixed

> Monitors are not created on Stratos restart
> -------------------------------------------
>
>                 Key: STRATOS-1615
>                 URL: https://issues.apache.org/jira/browse/STRATOS-1615
>             Project: Stratos
>          Issue Type: Bug
>          Components: Autoscaler
>    Affects Versions: 4.1.4
>            Reporter: Rajkumar Rajaratnam
>            Assignee: Rajkumar Rajaratnam
>            Priority: Blocker
>             Fix For: 4.1.5
>
>
> Root cause is, AS received the complete-topology-event before loading 
> application-contexts from registry to in-memory model. So the 
> complete-topology-event is ignored by AS, but the topology is initialized. 
> This also means that all the upcoming periodic complete-topology-events will 
> be ignored by AS.
> This should be fixed by starting event receiver threads after loading 
> policies/contexts from registry. 



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)