... there is a similar situation in JMXEnv.java:138. It seems that "ensureOnly" gets call before the previously invoked shutdown has completed. The problem here is that one needs the Jenkins build in order to test what is really happening :-(
On Thu, Dec 12, 2013 at 7:57 PM, German Blanco < [email protected]> wrote: > Hello Flavio, > > this looks great now, only one small problem and the deployment to go! > Congratulations! > > I have taken a look at the windows build in Jenkins, and I am going to > make a wild guess at what it might be happening, I hope it is worth > anything. > In many of the errors, the assertion in JMXEnv.java:115 is failing. > The call is from ClientBase.java:197. I see something strange there, it > seems that the procedure might close the client in one of the conditions > (line 193) and still then check that it is there in line 197. So if closing > is fast enough, the checking fails. Could that be it? > > Regards, > > German. > > > On Thu, Dec 12, 2013 at 5:24 PM, FPJ <[email protected]> wrote: > >> There are two issues blocking 3.4.6 now: >> >> >> >> - I don't understand why the 3.4 windows build in failing on >> Jenkins. Tests seem to pass fine on Windows for me. If anyone is willing >> to >> have a look, I would appreciate some help. >> >> - ZK-1430 needs to get in and I'd like to understand what needs >> to >> be done for ZK-1402. >> >> >> >> Thanks, >> >> -Flavio >> >> >