A word of warning - some of the error codes kannel SMPP emits are in decimal
rather than the hexadecimal they appear to be. I submitted a patch a couple
of weeks ago to fix the 3 lines that are wrong, but it hasn't made it into
CVS.

The SMPP complete specs are available from:
http://www.smsforum.net/doc/public/Spec/index.html

Simon

> -----Original Message-----
> From: [EMAIL PROTECTED]
> [mailto:[EMAIL PROTECTED]]On Behalf Of Alex Judd
> Sent: 23 April 2002 11:48
> To: Steffen Lindemann
> Cc: [EMAIL PROTECTED]
> Subject: Re: SMPP error code (0x00000069)
>
>
> 69 Decimal is 45 Hex which according to the SMPP 3.3 specification is
>
> "Submit SM/Multi failed. the Mobile (ESM) doesnot have the
> SMS service
> activated"
>
> There is a really good error message summary in a document I
> got from the
> Geeks Co site for their smartSMPP product which has them all
> summarised in
> Appendix B. I can probably dig it up if you can't find it.
>
> Alex
>
> On
> Tue, 23 Apr 2002, Steffen Lindemann wrote:
>
> > Hi,
> >
> > Does somebody have the list of error codes from a logical smsc.
> > When I send it gives me a error code 69 and the message:
> > "Warning: smpp: pdu nul terminated string has no nul"
> > and
> > "error: smpp: smsc returned error code 0x00000069 in
> response to submit_sm"
> >
> > any idea?
> >
> > Steffen
> >
> >
>
> --
> Alex Judd
> http://www.skywire.co.uk
>
>


Reply via email to