This is not quite true. Xtimer works fine with the ultra low power 32khz oscillator on SAMR21, it just needs a little reconfiguration. We have duty cycling nodes working ok with gnrc.
On Nov 21, 2017 8:26 AM, "Robert Hartung" <hart...@ibr.cs.tu-bs.de> wrote: > That's the 'only' issue. Problem: xtimer is guaranteed to have 1usec of > resolution. Most low-power timers will only have 8bit resolution -> > xtimer cannot be used. > > On 21.11.2017 15:07, Francisco Molina wrote: > > > >>Issues #7743 and #7332 both discuss the problem. > >> > >>Dan > > > > I saw those issues but they only refer to the fact that xtimer doesn't > > run during sleep modes, is that the only issue? Cheers > > > > Francisco > > > > > > _______________________________________________ > > devel mailing list > > devel@riot-os.org > > https://lists.riot-os.org/mailman/listinfo/devel > > > > -- > Robert Hartung, M.Sc. > > Technische Universität Braunschweig > Institut für Betriebssysteme und Rechnerverbund > Mühlenpfordtstr. 23, Raum 115 > 38106 Braunschweig > > Fon: +49 (531) 391 - 3264 > Fax: +49 (531) 391 - 5936 > E-Mail: hart...@ibr.cs.tu-bs.de > _______________________________________________ > devel mailing list > devel@riot-os.org > https://lists.riot-os.org/mailman/listinfo/devel >