With default config on smdk5250 latest tree throws below message :

[    2.226049] thermal thermal_zone0: critical temperature reached(224 
C),shutting down
[    2.227840] reboot: Failed to start orderly shutdown: forcing the issue

and hangs randomly because it reads wrong temperature value.

I can't figure out any direct relation between LDO10 and TMU from board
schematics which I have. So making LDO10 always-on to fix issue for now.

Signed-off-by: Yadwinder Singh Brar <yadi.b...@samsung.com>
---
 arch/arm/boot/dts/exynos5250-smdk5250.dts |    1 +
 1 files changed, 1 insertions(+), 0 deletions(-)

diff --git a/arch/arm/boot/dts/exynos5250-smdk5250.dts 
b/arch/arm/boot/dts/exynos5250-smdk5250.dts
index bc27cc2..95b5b51 100644
--- a/arch/arm/boot/dts/exynos5250-smdk5250.dts
+++ b/arch/arm/boot/dts/exynos5250-smdk5250.dts
@@ -190,6 +190,7 @@
                                regulator-name = "P1.8V_LDO_OUT10";
                                regulator-min-microvolt = <1800000>;
                                regulator-max-microvolt = <1800000>;
+                               regulator-always-on;
                        };
 
                        ldo11_reg: LDO11 {
-- 
1.7.0.4

--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html