(drum roll please .....)
 
AND NOW, LADIES & GENTLEMEN, THE MOMENT YOU'VE ALL BEEN WAITING FOR ...
 
Ok, enough hype, on to the real post.
 
Last night I finished my cap replacement in the R4A.  I replaced the PS filter cap module and, while I was at it, the handful of paper caps that "should oughta be replaced".  I also put in new blue filter material.
 
Overall, the replacement process was fairly easy.  My R4A is a 13 tube model which only used 3 of the 4 caps on the new filter cap module which was fine.  The effort went smoothly, although it did take a few hours.
 
Prior to the replacement I saw a few small issues with the receiver.  There was some AC hum in the audio.  CW tones were a bit raspy (not really noticeably on SSB).  The RX background tended to modulate up and down just a bit as did signals.  RX audio had a bit of a narrow sound to it with limited lows and highs, regardless of the PBT setting.  Also, there is significant loss in the .4 position but I didn't expect some cap changes to affect that.
 
Once I changed the caps, I turned the rig on and was quite happy to have no smoke!  Like a teenager in the morning, the radio slowly rose to life.  I give it a few minutes to warm up and then started listening using headphones.
 
I still have some DC on the audio but it is not as strong.  I think this is just the way these rigs are as my 2B also shows some DC on the audio.  The slightly raspy CW tone is still there.  The narrowness to the sound is still there as well.  The slight pumping of the gain seems to be gone.
 
I have some hope the narrowness to the sound and the loss in the .4 position are both related to PBT alignment.  I may do some o-scope signal tracing to see if I can find when the CW tone goes from clean to raspy.  Hopefully this is just an issue with a tube. 
 
- Keith KD1E -