Good Morning All,

Well, I'm VERY pleased to report that, in the process of getting access for the 
removal of my B+ voltage monitoring meter from the front of my amplifier, the 
doggone thing has returned to normal again...!

I undid umpteen screws, knobs, spacers, protective screens, ad nauseam to get 
the thing removed ---  somehow during all of this electronic compontentry feat 
of gymnastics, whatever it was that whacked-out the meter movement yesterday & 
prevented it from dropping back down to zero, became "re-set". 

Chalk one up to "...industrial phenomenon."

I couldn't really tap the meter before, when it was securely in place, to free 
anything up that might have temorarily "...snafu'ed" inside, because of the 
bulk of the amplifier surrounding it....looks like the bump & grind of its 
removal worked wonders for it, though, and me...

I laughed at myself when I held a perfectly normal meter staring me in the face 
at the end of it all, because I thought right away of one of the Apollo moon 
landing missions, when an astronaut's camera on the lunar surface refused to 
work...what did he do to fix it so far away from home? He tapped the thing!

I believe history records that it worked fine after that.

Many thanks to all for the sage & knowledgable advice that was imparted to me 
these past coupla days --- there is a real watershed of smart people out there 
who really know their stuff in such matters, and I salute you...!

Should those folks who offered to look for a direct replacement for this meter 
in their respective junque boxes still care to do so, I'll be only too pleased 
to consumate the deal --- after all, spares are always a good thing...

Thanks again, & my vy

~73!~ Eddy VE3CUI - VE3XZ


*****************************************

  Good Day All, 

  I wonder if anyone reading this has ever come up with a possible solution to 
what I have here in the matter of panel meters...?

  Specifically, I use an older Simpson brand 0-500 VDC meter to monitor the 
plate voltage of my 2x813 homebrewed linear amplifier (I employ multipliers to 
expand its scale to read 0-5000 VDC): to-day, while doing some trouble-shooting 
on the rig, there was a momentary internal short --- as a consequence of this, 
the meter needle now will NOT return to its "zero" peg, but rather, hangs-up at 
around the 2 KV point on the dial...

  When I activate the B+ on the power supply, the needle travels right back up 
to 2.5 KV, as it normally does, but again --- with the supply off --- the 
needle refuses to drop down past about 2 KV anymore.

  Is there any "fix" for this condition, or is a replacement meter in order...?

  If it's the latter(!), I need a 2-1/4" x 2-1/4" bakelite Simpson, 0-500 VDC 
unit...please check your junque boxes...!

  Thank-you...

  ~73~ Eddy VE3CUI - VE3XZ

Reply via email to