My R4B crystal calibrator has been acting erratically.

Often does not function until the R4B has been on for 20 minutes or so.
When I first turn on the calibrator function, I can initially hear it for
maybe 100msec, but it does not stay in oscillation.
And when it's being persnickety, when it does stay in oscillation, it
doesn't sound like a clean sine-wave.

Last night it was acting like this.  But just now, it was fine.  Came up
right off, sounded fine, and was working OK on 15 meters (didn't try 10
meters).

I recently did the Hayseed re-capping, so C190 was replaced, and after the
recapping it seemed to really help the crystal calibrator function, as it
was much worse before the recapping.

What else might I check ?  I see the calibrator circuitry on the schematic.
My scope is still down for repairs.

   Chuck, K1OM
_______________________________________________
Drakelist mailing list
[email protected]
http://mailman.zerobeat.net/mailman/listinfo/drakelist