Hi Jacopo,

Thank you for the patch.

On Thu, Jun 06, 2019 at 04:22:10PM +0200, Jacopo Mondi wrote:
> Add CMM units to Renesas R-Car H3 device tree and reference them from
> the Display Unit they are connected to.
> 
> While at it, re-sort the du device node properties to match the ordering
> found in other SoCs.
> 
> Signed-off-by: Jacopo Mondi <jacopo+rene...@jmondi.org>

Reviewed-by: Laurent Pinchart <laurent.pinch...@ideasonboard.com>

> ---
>  arch/arm64/boot/dts/renesas/r8a7795.dtsi | 36 +++++++++++++++++++++++-
>  1 file changed, 35 insertions(+), 1 deletion(-)
> 
> diff --git a/arch/arm64/boot/dts/renesas/r8a7795.dtsi 
> b/arch/arm64/boot/dts/renesas/r8a7795.dtsi
> index abeac3059383..83edd9f12caa 100644
> --- a/arch/arm64/boot/dts/renesas/r8a7795.dtsi
> +++ b/arch/arm64/boot/dts/renesas/r8a7795.dtsi
> @@ -2825,6 +2825,38 @@
>                       renesas,fcp = <&fcpvi1>;
>               };
>  
> +             cmm0: cmm@fea40000 {
> +                     compatible = "renesas,cmm-gen3";
> +                     reg = <0 0xfea40000 0 0x1000>;
> +                     clocks = <&cpg CPG_MOD 711>;
> +                     power-domains = <&sysc R8A7795_PD_ALWAYS_ON>;
> +                     resets = <&cpg 711>;
> +             };
> +
> +             cmm1: cmm@fea50000 {
> +                     compatible = "renesas,cmm-gen3";
> +                     reg = <0 0xfea50000 0 0x1000>;
> +                     clocks = <&cpg CPG_MOD 710>;
> +                     power-domains = <&sysc R8A7795_PD_ALWAYS_ON>;
> +                     resets = <&cpg 710>;
> +             };
> +
> +             cmm2: cmm@fea60000 {
> +                     compatible = "renesas,cmm-gen3";
> +                     reg = <0 0xfea60000 0 0x1000>;
> +                     clocks = <&cpg CPG_MOD 709>;
> +                     power-domains = <&sysc R8A7795_PD_ALWAYS_ON>;
> +                     resets = <&cpg 709>;
> +             };
> +
> +             cmm3: cmm@fea70000 {
> +                     compatible = "renesas,cmm-gen3";
> +                     reg = <0 0xfea70000 0 0x1000>;
> +                     clocks = <&cpg CPG_MOD 708>;
> +                     power-domains = <&sysc R8A7795_PD_ALWAYS_ON>;
> +                     resets = <&cpg 708>;
> +             };
> +
>               csi20: csi2@fea80000 {
>                       compatible = "renesas,r8a7795-csi2";
>                       reg = <0 0xfea80000 0 0x10000>;
> @@ -3028,9 +3060,11 @@
>                                <&cpg CPG_MOD 722>,
>                                <&cpg CPG_MOD 721>;
>                       clock-names = "du.0", "du.1", "du.2", "du.3";
> -                     vsps = <&vspd0 0 &vspd1 0 &vspd2 0 &vspd0 1>;
>                       status = "disabled";
>  
> +                     vsps = <&vspd0 0 &vspd1 0 &vspd2 0 &vspd0 1>;
> +                     cmms = <&cmm0 &cmm1 &cmm2 &cmm3>;
> +
>                       ports {
>                               #address-cells = <1>;
>                               #size-cells = <0>;
> -- 
> 2.21.0
> 

-- 
Regards,

Laurent Pinchart

Reply via email to