On 12/3/20 4:09 PM, Daniel Lezcano wrote:
On 03/12/2020 16:38, Lukasz Luba wrote:
On 12/3/20 1:09 PM, Daniel Lezcano wrote:
On 18/11/2020 13:03, Lukasz Luba wrote:
Devfreq cooling needs to now the correct status of the device in order
to operate. Do not rely on Devfreq last_status which might be a stale
data
and get more up-to-date values of the load.
Devfreq framework can change the device status in the background. To
mitigate this situation make a copy of the status structure and use it
for internal calculations.
In addition this patch adds normalization function, which also makes
sure
that whatever data comes from the device, it is in a sane range.
Signed-off-by: Lukasz Luba <lukasz.l...@arm.com>
---
drivers/thermal/devfreq_cooling.c | 52 +++++++++++++++++++++++++------
1 file changed, 43 insertions(+), 9 deletions(-)
diff --git a/drivers/thermal/devfreq_cooling.c
b/drivers/thermal/devfreq_cooling.c
index 659c0143c9f0..925523694462 100644
--- a/drivers/thermal/devfreq_cooling.c
+++ b/drivers/thermal/devfreq_cooling.c
@@ -227,20 +227,46 @@ static inline unsigned long
get_total_power(struct devfreq_cooling_device *dfc,
voltage);
}
+static void _normalize_load(struct devfreq_dev_status *status)
+{
+ /* Make some space if needed */
+ if (status->busy_time > 0xffff) {
+ status->busy_time >>= 10;
+ status->total_time >>= 10;
+ }
+
+ if (status->busy_time > status->total_time)
+ status->busy_time = status->total_time;
How the condition above is possible?
They should, be checked by the driver, but I cannot trust
and have to check for all corner cases: (div by 0, overflow
one of them, etc). The busy_time and total_time are unsigned long,
which means 4B on 32bit machines.
If these values are coming from device counters, which count every
busy cycle and total cycles of a clock of a device running at e.g.
1GHz they would overflow every ~4s.
I don't think it is up to this routine to check the driver is correctly
implemented, especially at every call to get_requested_power.
If the normalization ends up by doing this kind of thing, there is
certainly something wrong in the 'status' computation to be fixed before
submitting this series.
Normally IPA polling are 1s and 100ms, it's platform specific. But there
are also 'empty' periods when IPA sees temperature very low and does not
even call the .get_requested_power() callbacks for the cooling devices,
just grants max freq to all. This is problematic. I am investigating it
and will propose a solution for IPA soon.
I would avoid all of this if devfreq core would have default for all
devices a reliable polling timer... Let me check some possibilities also
for this case.
Ok, may be create an API to compute the 'idle,busy,total times' to be
used by the different the devfreq drivers and then fix the overflow in
this common place.
Yes, I have this plan, but I have to close this patch series. To go
forward with this, I will drop the normalization function and will keep
only the code of safe copy of the 'status', so using busy_time and
total_time will be safe.
I will address this computation and normalization in different patch
series. There might be a need of a new API as you pointed out, which
is out-of-scope of this patch set.
+ status->busy_time *= 100;
+ status->busy_time /= status->total_time ? : 1;
+
+ /* Avoid division by 0 */
+ status->busy_time = status->busy_time ? : 1;
+ status->total_time = 100;
Why not base the normalization on 1024? and use an intermediate u64.
You are the 2nd reviewer who is asking this. I tried to keep 'load' as
in range [0, 100] since we also have 'load' in cpufreq cooling in this
range. Maybe I should switch to 1024 (Ionela was also asking for this).
Well it is common practice to compute normalization with 1024 because
the division is a bit shift and the compiler optimize the code very well
with that value.
I will keep this 1024 in mind for the next topic series.
Regards,