Quoting Kuogee Hsieh (2021-08-04 08:51:01)
> Currently at dp_pm_resume() is_connected state is decided base on hpd 
> connection
> status only. This will put is_connected in wrongly "true" state at the 
> scenario
> that dongle attached to DUT but without hmdi cable connecting to it. Fix this
> problem by adding read sink count from dongle and decided is_connected state 
> base
> on both sink count and hpd connection status.
>
> Changes in v2:
> -- remove dp_get_sink_count() cand call drm_dp_read_sink_count()
>
> Changes in v3:
> -- delete status local variable from dp_pm_resume()
>
> Changes in v4:
> -- delete un necessary comment at dp_pm_resume()
>
> Fixes: d9aa6571b28ba ("drm/msm/dp: check sink_count before update 
> is_connected status")
> Signed-off-by: Kuogee Hsieh <khs...@codeaurora.org>
> ---

Tested-by: Stephen Boyd <swb...@chromium.org>
Reviewed-by: Stephen Boyd <swb...@chromium.org>

Reply via email to