On Sat, 14 Oct 2023, Alvin Šipraga <al...@pqrs.dk> wrote:
> From: Alvin Šipraga <a...@bang-olufsen.dk>
>
> The adv7511 driver is solely responsible for setting the physical
> address of its CEC adapter. To do this, it must read the EDID. However,
> EDID is only read when either the drm_bridge_funcs :: get_edid or
> drm_connector_helper_funcs :: get_modes ops are called. Without loss of
> generality, it cannot be assumed that these ops are called when a sink
> gets attached. Therefore there exist scenarios in which the CEC physical
> address will be invalid (f.f.f.f), rendering the CEC adapter inoperable.
>
> Address this problem by always fetching the EDID in the HPD work when we
> detect a connection. The CEC physical address is set in the process.
>
> Signed-off-by: Alvin Šipraga <a...@bang-olufsen.dk>
> ---
> Pardon the insertion of the ugly adv7511_get_edid() prototype, but I did
> not want to clobber git history by rearranging a bunch of functions. If
> this is the preferred approach I will happily re-spin the patch.
> ---
>  drivers/gpu/drm/bridge/adv7511/adv7511_drv.c | 6 ++++++
>  1 file changed, 6 insertions(+)
>
> diff --git a/drivers/gpu/drm/bridge/adv7511/adv7511_drv.c 
> b/drivers/gpu/drm/bridge/adv7511/adv7511_drv.c
> index 2611afd2c1c1..3d32c109963c 100644
> --- a/drivers/gpu/drm/bridge/adv7511/adv7511_drv.c
> +++ b/drivers/gpu/drm/bridge/adv7511/adv7511_drv.c
> @@ -424,6 +424,9 @@ static bool adv7511_hpd(struct adv7511 *adv7511)
>       return false;
>  }
>  
> +static struct edid *adv7511_get_edid(struct adv7511 *adv7511,
> +                                  struct drm_connector *connector);
> +
>  static void adv7511_hpd_work(struct work_struct *work)
>  {
>       struct adv7511 *adv7511 = container_of(work, struct adv7511, hpd_work);
> @@ -457,6 +460,9 @@ static void adv7511_hpd_work(struct work_struct *work)
>               if (adv7511->connector.dev) {
>                       if (status == connector_status_disconnected)
>                               cec_phys_addr_invalidate(adv7511->cec_adap);
> +                     else
> +                             adv7511_get_edid(adv7511, &adv7511->connector);

This leaks the returned EDID.

BR,
Jani.

> +
>                       drm_kms_helper_hotplug_event(adv7511->connector.dev);
>               } else {
>                       drm_bridge_hpd_notify(&adv7511->bridge, status);
>
> ---
> base-commit: 4366faf43308bd91c59a20c43a9f853a9c3bb6e4
> change-id: 20231014-adv7511-cec-edid-ff75bd3ac929
>

-- 
Jani Nikula, Intel

Reply via email to