Hi Liu, sorry I didn't fully answer you please see below.
On 25-12-08, Liu Ying wrote: > Hi Marco, > > On 12/02/2025, Marco Felsch wrote: > > From: Liu Ying <[email protected]> > > > > i.MX93 SoC mediamix blk-ctrl contains one DISPLAY_MUX register which > > configures parallel display format by using the "PARALLEL_DISP_FORMAT" > > field. Document the Parallel Display Format Configuration(PDFC) subnode > > and add the subnode to example. > > > > Signed-off-by: Liu Ying <[email protected]> > > [[email protected]: port to v6.18-rc1] > > [[email protected]: add bus-width] > > Signed-off-by: Marco Felsch <[email protected]> > > --- > > .../bindings/soc/imx/fsl,imx93-media-blk-ctrl.yaml | 92 > > ++++++++++++++++++++++ > > 1 file changed, 92 insertions(+) > > > > diff --git > > a/Documentation/devicetree/bindings/soc/imx/fsl,imx93-media-blk-ctrl.yaml > > b/Documentation/devicetree/bindings/soc/imx/fsl,imx93-media-blk-ctrl.yaml > > index > > 34aea58094e55365a2f9c86092f637e533f954ff..6e2d86d9341c75108b492bcbabc8a560d8e707cd > > 100644 > > --- > > a/Documentation/devicetree/bindings/soc/imx/fsl,imx93-media-blk-ctrl.yaml > > +++ > > b/Documentation/devicetree/bindings/soc/imx/fsl,imx93-media-blk-ctrl.yaml > > @@ -26,6 +26,12 @@ properties: > > reg: > > maxItems: 1 ... > > + properties: > > + endpoint: > > + $ref: /schemas/graph.yaml#/$defs/endpoint-base > > + unevaluatedProperties: false > > + > > + properties: > > + bus-width: > > In v1-v5, I thought the output bus format can be determined by the sink > device(a panel or a bridge) hence properties like bus-width were not needed. > But, if this property is really needed, then reference video-interfaces.yaml > since bus-width is documented there. Should we reference bus-type defined > in video-interfaces.yaml too? You're right, the bus-width should be determined by the connected panel. But there are cases where a 24-bit panel is connected but only the lower 18-bits are muxed. I added the bus-width property to handle this case. In the end most users don't have to specify this since the correct bus-width is coming from the panel bus-fmt. > > + enum: [ 16, 18, 24 ] > > The PARALLEL_DISP_FORMAT field of DISPLAY_MUX register says this IP supports > below formats. It seems that the enum here may tell RGB888, RGB666 and > RGB565. > How can we tell RGB555, YCbCr 24 bits and YUV444 then? > > 000b RGB888 -> RGB888 > 001b RGB888 -> RGB666 > 010b RGB565 -> RGB565 > 011b RGB555 -> RGB555 > 100b YUV -> YCbCr 24 bits > 101b YUV -> YUV444 This enum is about the physical bus width. RGB565 == 16-bit, YUV == 24-bit. That said, I don't think that you need to specify the bus-fmt since this is coming from the panel. As said above, my itension with the bus-width property is to provide integrators (dts-writers) a possibility to limit the physical available bus width. > > + description: > > + Specify the physical parallel bus width. > > + > > + This property is optional if the display bus-width > > + matches the SoC bus-width, e.g. a 18-bit RGB666 > > (display) > > + is connected and all 18-bit data lanes are muxed to > > the > > Per video-interfaces.yaml, s/data lanes/data lines/. "data lanes" is a > value for MIPI DSI/CSI, afaik. I can go with "lines" if this is the preferred naming convention for DRM. > > + parallel-output pads. > > How about just saying that this property is optional and by default it's 24? I wanted to make it clear what this property does. > > + This property must be set to 18 to cut only the LSBs > > + instead of the MSBs in case a 24-bit RGB888 display > > is > > + connected and only the lower 18-bit data lanes are > > muxed > > + to the parallel-output pads. > > The __lower__ 18-bit? Isn't it the __MSB__ 6bit in each color component? No, the LSB are cut, this is why it's so important to use this property if you connected a external 24-bit display to the lower data lines[17-0]. If you don't specify this property, the MSBs are cut/lost which is far worse than using the LSB information. Regards, Marco > > + > > + required: > > + - port@0 > > + - port@1 > > + > > + required: > > + - compatible > > + - reg > > + - ports > > + > > allOf: > > - if: > > properties: > > @@ -81,9 +141,12 @@ allOf: > > - const: isi > > - const: csi > > - const: dsi > > + > > required: > > - compatible > > - reg > > + - '#address-cells' > > + - '#size-cells' > > - power-domains > > - clocks > > - clock-names > > @@ -112,4 +175,33 @@ examples: > > clock-names = "apb", "axi", "nic", "disp", "cam", > > "pxp", "lcdif", "isi", "csi", "dsi"; > > #power-domain-cells = <1>; > > + #address-cells = <1>; > > + #size-cells = <1>; > > + > > + bridge@60 { > > + compatible = "nxp,imx93-pdfc"; > > + reg = <0x60 0x4>; > > + > > + ports { > > + #address-cells = <1>; > > + #size-cells = <0>; > > + > > + port@0 { > > + reg = <0>; > > + > > + pdfc_from_lcdif: endpoint { > > + remote-endpoint = <&lcdif_to_pdfc>; > > + }; > > + }; > > + > > + port@1 { > > + reg = <1>; > > + > > + pdfc_to_panel: endpoint { > > + remote-endpoint = <&panel_from_pdfc>; > > + bus-width = <18>; > > + }; > > + }; > > + }; > > + }; > > }; > > > > > -- > Regards, > Liu Ying > -- #gernperDu #CallMeByMyFirstName Pengutronix e.K. | | Steuerwalder Str. 21 | https://www.pengutronix.de/ | 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-9 |