On Wed, 07 Jan 2026 22:35:21 +0100, Marek Vasut wrote:
> Current binding document enforces presence of either port@0 (DSI in) or
> port@1 (DPI IN/OUT), with port@2 (DP out) being optional. This bridge is
> capable of DSI->DP, DPI->DP and DPI->DP, it is therefore perfectly valid
> to have both port@0 and port@1 described in the DT, because this is fairy
> standard DPI->DP configuration of this bridge. Replace oneOf with anyOf
> to cover this configuration.
> 
> Signed-off-by: Marek Vasut <[email protected]>
> ---
> Cc: Andrey Gusakov <[email protected]>
> Cc: Andrzej Hajda <[email protected]>
> Cc: Conor Dooley <[email protected]>
> Cc: David Airlie <[email protected]>
> Cc: Jernej Skrabec <[email protected]>
> Cc: Jonas Karlman <[email protected]>
> Cc: Krzysztof Kozlowski <[email protected]>
> Cc: Laurent Pinchart <[email protected]>
> Cc: Maarten Lankhorst <[email protected]>
> Cc: Maxime Ripard <[email protected]>
> Cc: Neil Armstrong <[email protected]>
> Cc: Rob Herring <[email protected]>
> Cc: Robert Foss <[email protected]>
> Cc: Simona Vetter <[email protected]>
> Cc: Thomas Zimmermann <[email protected]>
> Cc: [email protected]
> Cc: [email protected]
> Cc: [email protected]
> ---
>  .../devicetree/bindings/display/bridge/toshiba,tc358767.yaml    | 2 +-
>  1 file changed, 1 insertion(+), 1 deletion(-)
> 

Applied, thanks!