On 10/11/2026 9:00 AM, Shawn Guo wrote: > On Fri, Oct 09, 2026 at 02:36:38AM +0530, Akhil P Oommen wrote: >> From: Aastha Pandey <[email protected]> >> >> Unlike the CPU, the GPU does not throttle its speed automatically when >> it reaches high temperatures. >> >> Set up GPU cooling on Nord by throttling the Adreno 753 GPU when it >> reaches 105°C. Label the GPU thermal zones and their passive trip >> points, map them to the GPU as a cooling device, and add a passive >> polling delay so the thermal framework can monitor the zones while >> throttling. >> >> Signed-off-by: Aastha Pandey <[email protected]> >> Signed-off-by: Akhil P Oommen <[email protected]> >> --- >> arch/arm64/boot/dts/qcom/nord-embedded.dtsi | 177 >> ++++++++++++++++++++++++++++ >> arch/arm64/boot/dts/qcom/nord.dtsi | 80 ++++++------- >> 2 files changed, 217 insertions(+), 40 deletions(-) >> >> diff --git a/arch/arm64/boot/dts/qcom/nord-embedded.dtsi >> b/arch/arm64/boot/dts/qcom/nord-embedded.dtsi >> index 4379092b7bf8..23370007c974 100644 >> --- a/arch/arm64/boot/dts/qcom/nord-embedded.dtsi >> +++ b/arch/arm64/boot/dts/qcom/nord-embedded.dtsi >> @@ -17,6 +17,7 @@ >> #include <dt-bindings/interconnect/qcom,nord-rpmh.h> >> #include <dt-bindings/power/qcom,rpmhpd.h> >> #include <dt-bindings/soc/qcom,rpmh-rsc.h> >> +#include <dt-bindings/thermal/thermal.h> >> >> #include "nord.dtsi" >> >> @@ -2042,3 +2043,179 @@ opp-403000000 { >> }; >> }; >> }; >> + >> +&gpu_0_0_0_thermal { >> + polling-delay-passive = <10>; >> + >> + cooling-maps { >> + map0 { >> + trip = <&gpu_0_0_0_alert0>; >> + cooling-device = <&gpu_0 THERMAL_NO_LIMIT >> THERMAL_NO_LIMIT>; >> + }; >> + }; >> +}; > > I'm not sure why this is Embedded variant specific. Can we not just > update nord.dtsi as needed? Would that break GearVM variant in any way? Only Embedded variant support dvfs scaling. So passive thermal mitigations should be limited to that? -Akhil. > > Shawn
