Stewart Walters wrote:
Kyle McDonald wrote:
The one thing I can think of, is that IBM warns on these blades that the network connection for the BMC is shared (hijacked) from bge0, and that if you PXE boot over bge0, the PXE code will reset the bge interface in a way the will disconnect the SOL connection.

Given this, I wonder if the disconnection is a (delayed) consequence of the bge0 driver loading shortly before the disconnection?

   -Kyle
Just on that note, and I know this is going to sound like a typical IBM response, but have you taken the Bladecenter chassis BIOS, BMC and RSAII firmware revisions all to the latest level?

For that matter, have you also taken the Blade BIOS and BMC firmware to the latest revision?

I roll my eyes every time I get that response from IBM.
I know. It's like Windows service people asking you if you've rebooted yet.
But with the IBM Bladecenters - I just go straight to the latest firmware before I even call them now. Applying the latest firmware revisions often do fix up the quirky problems you can receive on BIOS's, BMC's and RSAII Adaptors.
When I ran in to this problem the first time (about a year ago) I did have them up to date.

I'll have to go check the current versions and download any I don't have, but since S10 is working fine, I didn't think of it.

 -Kyle


Regards,

Stewart
_______________________________________________
opensolaris-discuss mailing list
[email protected]

_______________________________________________
driver-discuss mailing list
[email protected]
http://mail.opensolaris.org/mailman/listinfo/driver-discuss

Reply via email to