module /platform/i86pc/kernel/amd64/unix: text at [0xfffffffffb800000,
0xfffffffffb938f93] data at 0xfffffffffbc00000
module /kernel/amd64/genunix: text at [0xfffffffffb938fa0,
0xfffffffffbb8f897] data at 0xfffffffffbc80b40
Loading kmdb...
module /kernel/misc/amd64/kmdbmod: text at [0xfffffffffbcf0730,
0xfffffffffbd939a7] data at 0xfffffffffbd939b0
module /kernel/misc/amd64/ctf: text at [0xfffffffffbb8f8a0,
0xfffffffffbb9a1f7] data at 0xfffffffffbdaed10
Welcome to kmdb
kmdb: unable to determine terminal type: assuming `vt100'
Loaded modules: [ unix krtld genunix ]
[0]> moddebug?W 0x80000000
moddebug: 0 = 0x80000000
[0]> :c
OP: 1: param 'nfs_global_client_only' was '0x0' in module: '<null
string>'.
now it is set to '0x1'.
SunOS Release 5.11 Version snv_125 64-bit
Copyright 1983-2009 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.
features:
614dffff<cpuid,mwait,cx16,sse3,asysc,htt,sse2,sse,sep,pat,cx8,pae,mca,mmx,cmov,de,pge,mtrr,msr,tsc,lgpg>
mem = 8387812K (0x1fff39000)
load 'fs/fifofs' id 6 loaded @ 0xfffffffff7801000/0xfffffffffbdb30a0
size 17904/184
load 'fs/specfs' id 5 loaded @ 0xfffffffff77fb000/0xfffffffffbdb3000
size 23952/160
installing specfs, module id 5.
installing fifofs, module id 6.
load 'fs/devfs' id 8 loaded @ 0xfffffffff7806000/0xfffffffffbdb3cb1
size 22808/584
installing devfs, module id 8.
load 'misc/mac' id 11 loaded @ 0xfffffffff7824000/0xfffffffffbdb4825
size 149536/2072
load 'misc/dls' id 10 loaded @ 0xfffffffff781d000/0xfffffffffbdb451d
size 25920/776
load 'fs/dev' id 9 loaded @ 0xfffffffff780c000/0xfffffffffbdb3f1d size
69456/1536
installing dev, module id 9.
installing dls, module id 10.
installing mac, module id 11.
load 'sched/TS' id 13 loaded @ 0xfffffffff784e000/0xfffffffffbdb5152
size 14712/2016
installing TS, module id 13.
load 'sched/TS_DPTBL' id 14 loaded @
0xfffffffffbbffdd0/0xfffffffffbdb5952 size 440/2096
installing TS_DPTBL, module id 14.
load 'misc/acpica' id 16 loaded @
0xfffffffff785b000/0xfffffffffbdb686a size 386696/4648
load 'misc/acpidev' id 15 loaded @
0xfffffffff7852000/0xfffffffffbdb6182 size 36480/1768
installing acpidev, module id 15.
installing acpica, module id 16.
load 'misc/pci_autoconfig' id 17 loaded @
0xfffffffff78ba000/0xfffffffffbdb8056 size 47128/344
installing pci_autoconfig, module id 17.
load 'misc/busra' id 19 loaded @ 0xfffffffff78ca000/0xfffffffffbdba6d6
size 8656/96
load 'drv/isa' id 18 loaded @ 0xfffffffff78c6000/0xfffffffffbdba1ce
size 14056/1288
installing isa, module id 18.
installing busra, module id 19.
Using default device instance data
load 'cpu/cpu.generic' id 20 loaded @
0xfffffffff78cd000/0xfffffffffbdba75e size 16544/1904
installing cpu.generic, module id 20.
load 'cpu/cpu_ms.GenuineIntel' id 21 loaded @
0xfffffffff78d4000/0xfffffffffbdbaecf size 4400/120
installing cpu_ms.GenuineIntel, module id 21.
initialized model-specific module 'cpu_ms.GenuineIntel' on chip 0 core
0 strand 0
load 'mach/uppc' id 22 loaded @ 0xfffffffff78d6000/0xfffffffffbdbafbf
size 14904/472
installing uppc, module id 22.
load 'mach/pcplusmp' id 24 loaded @
0xfffffffff78dc000/0xfffffffffbdbc367 size 69048/1952
installing pcplusmp, module id 24.
load 'misc/iommulib' id 26 loaded @
0xfffffffff7900000/0xfffffffffbdc1578 size 11632/144
load 'drv/rootnex' id 25 loaded @
0xfffffffff78ef000/0xfffffffffbdc0cb8 size 67000/2240
installing rootnex, module id 25.
installing iommulib, module id 26.
root nexus = i86pc
load 'drv/options' id 27 loaded @
0xfffffffff78ecdb8/0xfffffffffbdc1674 size 584/192
installing options, module id 27.
load 'drv/pseudo' id 28 loaded @ 0xfffffffff7823540/0xfffffffffbdc1734
size 2688/560
installing pseudo, module id 28.
pseudo0 at root
pseudo0 is /pseudo
load 'drv/clone' id 29 loaded @ 0xfffffffff78d9a38/0xfffffffffbdc1964
size 1312/568
installing clone, module id 29.
load 'misc/scsi' id 31 loaded @ 0xfffffffff7918000/0xfffffffffbdc1dc4
size 83968/15408
load 'drv/scsi_vhci' id 30 loaded @
0xfffffffff7906000/0xfffffffffbdc1b9c size 73560/552
installing scsi_vhci, module id 30.
installing scsi, module id 31.
load 'misc/scsi_vhci/scsi_vhci_f_asym_sun' id 32 loaded @
0xfffffffff78d5130/0xfffffffffbdc5b5a size 3768/208
installing scsi_vhci_f_asym_sun, module id 32.
load 'misc/scsi_vhci/scsi_vhci_f_asym_lsi' id 33 loaded @
0xfffffffff7930000/0xfffffffffbdc5c2a size 7368/632
installing scsi_vhci_f_asym_lsi, module id 33.
load 'misc/scsi_vhci/scsi_vhci_f_asym_emc' id 34 loaded @
0xfffffffff7932000/0xfffffffffbdc5ea2 size 4392/232
installing scsi_vhci_f_asym_emc, module id 34.
load 'misc/scsi_vhci/scsi_vhci_f_sym_emc' id 35 loaded @
0xfffffffff78d3be8/0xfffffffffbdc5f8a size 904/208
installing scsi_vhci_f_sym_emc, module id 35.
load 'misc/scsi_vhci/scsi_vhci_f_sym_hds' id 36 loaded @
0xfffffffff7848820/0xfffffffffbdc605a size 1864/200
installing scsi_vhci_f_sym_hds, module id 36.
load 'misc/scsi_vhci/scsi_vhci_f_sym' id 37 loaded @
0xfffffffff7851978/0xfffffffffbdc6122 size 1512/328
installing scsi_vhci_f_sym, module id 37.
load 'misc/scsi_vhci/scsi_vhci_f_tpgs' id 38 loaded @
0xfffffffff78cc1d0/0xfffffffffbdc626a size 2896/192
installing scsi_vhci_f_tpgs, module id 38.
scsi_vhci0 at root
scsi_vhci0 is /scsi_vhci
load 'misc/hpcsvc' id 41 loaded @
0xfffffffff7943000/0xfffffffffbdc706a size 5608/104
load 'misc/pcihp' id 40 loaded @ 0xfffffffff793d000/0xfffffffffbdc6f5a
size 22408/272
load 'misc/pcie' id 42 loaded @ 0xfffffffff7945000/0xfffffffffbdc70d2
size 33752/160
load 'drv/npe' id 39 loaded @ 0xfffffffff7934000/0xfffffffffbdc632a
size 35104/3120
installing npe, module id 39.
installing pcihp, module id 40.
installing hpcsvc, module id 41.
installing pcie, module id 42.
npe0 at root: space 0 offset 0
npe0 is /p...@0,0
PCI Express-device: i...@1f, isa0
load 'drv/amd_iommu' id 43 loaded @
0xfffffffff794e000/0xfffffffffbdc71a2 size 59496/688
installing amd_iommu, module id 43.
unloading amd_iommu, module id 43, loadcnt 1.
NOTICE: Invalid iBFT table 0x1
load 'misc/fssnap_if' id 46 loaded @
0xfffffffff7931cc8/0xfffffffffbdc8a82 size 800/136
load 'fs/ufs' id 45 loaded @ 0xfffffffff794e000/0xfffffffffbdc71a2
size 263624/6368
installing ufs, module id 45.
installing fssnap_if, module id 46.
load 'drv/acpippm' id 47 loaded @
0xfffffffff78055f0/0xfffffffffbdc942a size 2528/360
installing acpippm, module id 47.
pseudo-device: acpippm0
acpippm0 is /pseudo/acpi...@0
load 'drv/ppm' id 48 loaded @ 0xfffffffff7993000/0xfffffffffbdc9592
size 23936/1136
installing ppm, module id 48.
pseudo-device: ppm0
ppm0 is /pseudo/p...@0
load 'drv/ramdisk' id 49 loaded @
0xfffffffff7999000/0xfffffffffbdc9a22 size 10624/376
installing ramdisk, module id 49.
ramdisk0 at root
ramdisk0 is /ramdisk
root on /ramdisk:a fstype ufs
load 'fs/ctfs' id 50 loaded @ 0xfffffffff799c000/0xfffffffffbdc9b9a
size 16040/888
installing ctfs, module id 50.
load 'fs/procfs' id 51 loaded @ 0xfffffffff79a0000/0xfffffffffbdc9f72
size 132696/2688
installing procfs, module id 51.
load 'fs/mntfs' id 52 loaded @ 0xfffffffff79c1000/0xfffffffffbdcaa06
size 12024/176
installing mntfs, module id 52.
load 'fs/tmpfs' id 53 loaded @ 0xfffffffff79c4000/0xfffffffffbdcaac6
size 29448/66432
installing tmpfs, module id 53.
load 'fs/objfs' id 54 loaded @ 0xfffffffff79cc000/0xfffffffffbddae6e
size 9488/1000
installing objfs, module id 54.
load 'fs/sharefs' id 55 loaded @ 0xfffffffff79cf000/0xfffffffffbddb276
size 9344/1344
installing sharefs, module id 55.
SMBIOS v2.3 loaded (2026 bytes)load 'drv/acpinex' id 56 loaded @
0xfffffffff79d2000/0xfffffffffbddb81e size 4504/576
installing acpinex, module id 56.
acpinex0 at root
acpinex0 is /fw
load 'drv/cpudrv' id 57 loaded @ 0xfffffffff79d4000/0xfffffffffbddba5e
size 9952/224
installing cpudrv, module id 57.
load 'misc/kcf' id 62 loaded @ 0xfffffffff7b79000/0xfffffffffbdee36e
size 165160/3192
load 'misc/md5' id 61 loaded @ 0xfffffffff7b76000/0xfffffffffbdee096
size 10528/728
load 'misc/sha1' id 64 loaded @ 0xfffffffff7ba4000/0xfffffffffbdf890e
size 14072/960
load 'crypto/swrand' id 63 loaded @
0xfffffffff7ba2000/0xfffffffffbdf7e7e size 7200/2704
load 'misc/hook' id 65 loaded @ 0xfffffffff7ba8000/0xfffffffffbdf8d06
size 16224/112
load 'misc/neti' id 66 loaded @ 0xfffffffff7bac000/0xfffffffffbdf8d77
size 10328/120
load 'drv/ip' id 60 loaded @ 0xfffffffff7a1a000/0xfffffffffbde0306
size 1422272/56720
load 'fs/sockfs' id 59 loaded @ 0xfffffffff79ee000/0xfffffffffbdde466
size 176296/7840
load 'sys/c2audit' id 58 loaded @
0xfffffffff79d7000/0xfffffffffbddbb4e size 90272/10520
installing c2audit, module id 58.
installing sockfs, module
system>