I'm stuck again fellas. I'm on the Part II Alignment and Test. Everything was going so well.... 4 MHz Oscillator Calibration......................passed PLL Reference Oscillator Range Test.......passed VCO 8-10 MHz Test............................. passed VCO 6 V Alignment.................................passed VCO Voltage Readings............................failed!!!!!!!!!!!
The voltage readings on 80, 17, 15,12, & 10 meters are fine. The 40 meter reading is .03V and doesn't change with frequency change The 30 meter reading is 8.13V and doesn't change with frequency change The 20 meter reading is .03V and doesn't change with frequency change. I've checked the capacitors (C71-C74) and diodes (D21-D26) All are placed correctly with good solder. L 30 is also correct I bought my toroids from Mychael so T5 is good. Any ideas? Dave N1PT _______________________________________________ Elecraft mailing list Post to: Elecraft@mailman.qth.net You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com