Thanks, Don. That's what I was guessing--but I wanted some "expert" opinions before I started tinning leads and soldering.
-john W4PAH On Thu, Sep 16, 2010 at 9:00 PM, Don Wilhelm <w3...@embarqmail.com> wrote: > John, > > The winding direction does not matter - just the turns ratio. So wind to so > the green turns do not cross over the red winding and it will be neater and > work just as well. > > 73, > Don W3FPR > > On 9/16/2010 8:42 PM, John Shadle wrote: >> >> I'm nearing the end of my K2 build, and am working on the KSB2 module >> at the moment. On page 11 of the most recent version of the manual >> (Rev E), it shows the secondary winding going "against the grain" of >> the primary winding. I really want to start with wire 2 on the same >> side of the toroid as wire 3. The picture shows wire 2 on the same >> side as wire 4. This makes winding more difficult and doesn't allow >> for me to "go parallel" to the primary winding. >> >> http://www.elecraft.com/manual/KSB2%20manual%20rev%20E.pdf >> >> Is this just a bad schematic, or does it matter what side of the core >> 1-2 are, relative to 3-4? >> >> Same goes for T2, since it uses the same schematic. >> > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html