Thanks, Don. That's what I was guessing--but I wanted some "expert"
opinions before I started tinning leads and soldering.

-john W4PAH

On Thu, Sep 16, 2010 at 9:00 PM, Don Wilhelm <w3...@embarqmail.com> wrote:
>  John,
>
> The winding direction does not matter - just the turns ratio.  So wind to so
> the green turns do not cross over the red winding and it will be neater and
> work just as well.
>
> 73,
> Don W3FPR
>
> On 9/16/2010 8:42 PM, John Shadle wrote:
>>
>> I'm nearing the end of my K2 build, and am working on the KSB2 module
>> at the moment. On page 11 of the most recent version of the manual
>> (Rev E), it shows the secondary winding going "against the grain" of
>> the primary winding. I really want to start with wire 2 on the same
>> side of the toroid as wire 3. The picture shows wire 2 on the same
>> side as wire 4. This makes winding more difficult and doesn't allow
>> for me to "go parallel" to the primary winding.
>>
>> http://www.elecraft.com/manual/KSB2%20manual%20rev%20E.pdf
>>
>> Is this just a bad schematic, or does it matter what side of the core
>> 1-2 are, relative to 3-4?
>>
>> Same goes for T2, since it uses the same schematic.
>>
>
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html