Stick with the correct number of turns. The inductance listed is a 
nominal calculated value and will vary from core to core, and with the 
frequency used to measure the inductance.

We also see a wide variance in inductance measurements between different 
instruments based on their differing test frequencies.

It -is- important that you confirm you are using the correct core, color 
etc.

73, Eric


On 6/1/2011 10:20 AM, rhapak wrote:
> Hi all!
> In the K2 manual it says to wind the toroids with the amount of turns
> specified and not to alter the windings to get the inductance specified in
> the parts list.
> I notice that many of my toroids do not measure near the stated inductance
> in the parts list but are wound with the specified amount of turns and would
> just like to know why??
>
> Thanks in advance,
> Rod
> VA3 ZVT
>
> --
> View this message in context: 
> http://elecraft.365791.n2.nabble.com/K2-Toroids-not-measuring-correct-inductance-tp6427961p6427961.html
> Sent from the Elecraft mailing list archive at Nabble.com.
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:Elecraft@mailman.qth.net
>
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to