If I may make a suggestion Paul, Among the many obvious solutions such as Velcro strapping or nylon ties around the ribbon cable there's also the option of using a flat cable clip or mount. An example is shown on this drawing from Panduit for their model FCC-A clips; < http://www.panduit.com/groups/MPM-GAWA/documents/PartDrawing/077542.pdf> Since the ribbon cable is located close to the left side of the P3 housing an adhesive flat cable clip easily holds the cable securely away from the TMP coaxial cable on the right side of the cabinet. Another clip could be used on the right side to hold the TMP cable further away from the ribbon cable. In a pinch a short length of hook & loop material (Velcro) around the ribbon cable seems to help also but I think the TMP cable needs to be supported close to the righthand side of the cabinet with a clip or perhaps a small adhesive tie mount and nylon tie. Gary N6LRV
-----Original Message----- From: elecraft-boun...@mailman.qth.net [mailto:elecraft-boun...@mailman.qth.net] On Behalf Of Paul Saffren N6HZ Sent: Friday, June 01, 2012 8:16 AM To: elecraft@mailman.qth.net Subject: Re: [Elecraft] P3 SVGA interference - Hi Bob, We're taking a look at it now. A shorter ribbon cable is a possibility, but maybe there is a simple way to dress the existing cable by folding it and holding it with some sort of clip. Just thinking out loud. -Paul ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html