With this software, there is an increased temptation to leave the internal counter probe connected inside the K2. While that is OK for the K2/10, for the K2/100 the probe should not be left plugged in because it can couple BFO harmonics into the KPA100 resulting in spurious emissions.

Elecraft recommends that the internal counter probe be removed if the KPA100 is installed. See the KPA100 manual page 55.

73,
Don W3FPR

On 3/9/2015 3:18 AM, Ken Chandler wrote:
Didn't realise it existed!
Will certainly be sorting the software today for my K2/100.



______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com

Reply via email to