With this software, there is an increased temptation to leave the
internal counter probe connected inside the K2.
While that is OK for the K2/10, for the K2/100 the probe should not be
left plugged in because it can couple BFO harmonics into the KPA100
resulting in spurious emissions.
Elecraft recommends that the internal counter probe be removed if the
KPA100 is installed. See the KPA100 manual page 55.
73,
Don W3FPR
On 3/9/2015 3:18 AM, Ken Chandler wrote:
Didn't realise it existed!
Will certainly be sorting the software today for my K2/100.