Fred,
I am now trying the KAT500 output going to a dummy load. When the K3 is set
at about 22 watts out, the KPA500 shows 440 Watts out. When I use the Tune
feature on the K3 with Manual Tune feature on the KAT500, there is no fault.
However, when I send with the K3 keyer and with Manual Tune on the KAT500, 
I get a fault on the KAT500. Using the KAT500 utility, I find Fault Code 03
- VFWD above relay hotswitch limit - VFWD 1551 VRFL 0 SWR 1.00 SWRB 1.00. Is
the moral of the story to use the K3 Tune control, not the K3 keyer?

73 de Dave w0ru



--
View this message in context: 
http://elecraft.365791.n2.nabble.com/KAT500-Fault-tp7608563p7608616.html
Sent from the Elecraft mailing list archive at Nabble.com.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com

Reply via email to