Fred, I am now trying the KAT500 output going to a dummy load. When the K3 is set at about 22 watts out, the KPA500 shows 440 Watts out. When I use the Tune feature on the K3 with Manual Tune feature on the KAT500, there is no fault. However, when I send with the K3 keyer and with Manual Tune on the KAT500, I get a fault on the KAT500. Using the KAT500 utility, I find Fault Code 03 - VFWD above relay hotswitch limit - VFWD 1551 VRFL 0 SWR 1.00 SWRB 1.00. Is the moral of the story to use the K3 Tune control, not the K3 keyer?
73 de Dave w0ru -- View this message in context: http://elecraft.365791.n2.nabble.com/KAT500-Fault-tp7608563p7608616.html Sent from the Elecraft mailing list archive at Nabble.com. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to arch...@mail-archive.com