My last post might have been too long, so I'll try again - just the facts:

Equipment:
KX3 S/N 7210, FW 02.25

Problem:
6M band -> VSWR 1.8:1 (KX3 meter) on 50ohm load connected directly to ant
connector (no cable).
ATU - bypass
Load verified good.
All other bands good.
ATU will match to 1:1 if enabled and tune requested.
After ATU match, 25ohm load yields 2:1 (KX3 meter test - OK).

MSG to Elecraft support unanswered (which seems uncharacteristic, based on
rep)

Looking for input on how to identify/fix problem.

Thanks,

Steve, WD4SDC.



--