One of the main failure modes of Li-Ion batteries is trying to charge a defective battery ( puffed pack). When Li-Ion batteries begin to fail one or more cells develop a high internal resistance and heat up during charging. The 2hr warning is likely driven by the danger of trying to charge a bad pack more than the a time limit for a good pack. For packs with built in management/balancing circuitry ( no access to individual cells) it is difficult to see a bad cell. If you are concerned, there are fireproof pouches to put the battery in during charging. You can get them from most major RC model sites.
-- View this message in context: http://elecraft.365791.n2.nabble.com/KX2-KXBT2-Charger-tp7617624p7620896.html Sent from the Elecraft mailing list archive at Nabble.com. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to arch...@mail-archive.com