I think 1.6:1 is high for that kind of dummy load, if it's in good shape. 
Should be close to 1:1.
Anyway, you can't really say there is a problem unless you have a better match. 
Current draw is sensitive to mismatch.
-- 
Vic

On May 9, 2020 2:32:15 AM GMT+03:00, Drew Arnett <arnett.d...@gmail.com> wrote:
>Walter,
>
>50 MHz TX constant 4 W carrier measures 13.53 V on DMM (outside the DC
>power plug), 13.3 V on KX3 meter, 2.9 A on KX3 meter and 1.6 to 1 VSWR
>on KX3 meter.  Microwave dummy load with BNC to N adapter.
>
>I didn't measure all of this when the rig was new, so have no baseline
>to know what is normal.  :-(
>
>Thanks,
>
>Drew
>n7da
>
>On Fri, May 8, 2020 at 11:19 PM Drew Arnett <arnett.d...@gmail.com>
>wrote:
>>
>> What do you see for current draw on the KX-3?  Manual says 1 to 2 A
>typical.
>>
>> I'm seeing 3 A at less than full power on one band.  Yikes!  Makes me
>> wonder if the repair shop is open?  Elecraft website says hunkered
>> down and mostly work from home.
>>
>> Thanks and best regards,
>>
>> Drew
>> n7da
>______________________________________________________________
>Elecraft mailing list
>Home: http://mailman.qth.net/mailman/listinfo/elecraft
>Help: http://mailman.qth.net/mmfaq.htm
>Post: mailto:Elecraft@mailman.qth.net
>
>This list hosted by: http://www.qsl.net
>Please help support this email list: http://www.qsl.net/donate.html
>Message delivered to k2vco....@gmail.com 
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com 

Reply via email to