On 11/13/2022 10:52 AM, Andy Durbin wrote:
Note that the drop is not related only to power output but is a function of 
total PA input power

It's also a function of IR drop in ALL of the AC wiring between the distribution panel and the amp. In North America, building codes call for at least #14 for circuits fused at 15A, and #12 for 20A. Copper is expensive, so larger sizes are rarely installed.

73, Jim K9YC