On Mon, Aug 27, 2007 at 12:16:17PM -0400, JT Croteau wrote:

> I have the counter probe on TP3 and measuring 12099 kHz as I should
> according to the manual.  However, it is changing back and forth
> somewhat rapidly between 12099.28 and 12099.29 kHz.  Is this normal or
> do I have something wrong with the PLL Reference Oscillator?

This is normal.  The frequency isn't changing - it is just that you 
occasionally have one more - or less - count during the gate time of
the frequency counter.  

Tree N6TR