did some more on the problem. With MixW using modes RTTY or RTTYR when controlled by a K3 in data mode the frequency scale moves to the right but the signal moves to the left. They should obviously be in step i.e the display should show a signal at a constant frequency as the radio is tuned. This works correctly in USB and LSB. MixW thinks the radio mixer frequency is on the opposite side of the signal to reality.

To attempt to solve the problem I reloaded the K3 software; no change. I then went back to the-non beta 2.02 etc software; everything now working correctly. I am pretty sure that this is a real problem but maybe only for MixW users using the RTTY modes. It is a problem for us though, because by using USB or LSB modes in MixW automatically switches the K3 to the same modes. This prevents use of the K3 data mode features such as prevention
of compression and other data special settings.

Julian (G4ILO) thanks for your interest. All my CAT corrections are zero in MixW also. Interesting that you say there was some change in the last release - "K3 was erroneously reporting the data modes as reversed" This looks very much like the problem but in the case of RTTY it seems it was correct but is now incorrect.

Hope this all gets sorted in version 2.11 Keep up the good work on the software and I agree with the release of beta
software so that we can test all the nooks and crannies.

73 Andrew M1KAZ

_______________________________________________
Elecraft mailing list
Post to: Elecraft@mailman.qth.net
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply via email to