Check that a long lead from the KSYN3 or KREF3 modules aren't shorted against 
the bare metal they mount to.  That was my problem.  One cap had a lead that 
was too long and was touching.
Rob
NV5E
K3 #1417

________________________________
From: [EMAIL PROTECTED]
To: elecraft@mailman.qth.net
Date: Wed, 1 Oct 2008 22:23:28 -0700
Subject: [Elecraft] Problems with K3 s/n 1826



I just finished building my new K3 (all except the 100W amp that
awaits final checkout). The rig seems to power up OK, but returns error messages
when I do the Synthesizer Calibration. It returns Err VCO with E 00374 data
and/or ERR VC4 with E 00039 data. I checked the seating of the oscillator, the
KREF3 and KSYN3 modules and the three TMP cables, but the results are the same.
What is going on and what can I do? Thank you.