Hi 
I´m just doing receiver signal tracing using the Elecraft RF probe. Coming to 
measure signal at U12 there are 300mV at pin 4 but only 1 or 2 mV at pin 8 no 
change if I increase the generator input or RF gain to max. The same with U11 
at pin 1, when I increase RF Gain I get n o more than 30mV at pin 5 of U11. 
Across the crystal filter I get only about 100 mV at W3 with 1,4 V at W2. Is 
that a matter of the filter circuit or the IF amp MC1350. Thanks for any help...

73
Peter, DF8BB (K2 6437)