Ok Ive completed the watt meter calibration and the radio and external 
meter both are in agreement now but a new problem has raised its head.  
( sort of remember this happening when I first put the rig together but 
the error didnt repeat).  When I do the Tx gain calibrate the utility 
says there is too high an swr (cantenna is still attached 50 ohm 
approx)  160 calibrates but the error (ERR TxG) starts there after on 60 
or 40.

More thoughts?  I wonder if Wayne watches email on the weekend.

Mike/aj9c
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html