Wayne & Gary, 
Thanks for the support off the list.
After I set PA TEMP to "R ONLY" instead of "T AND R",
the problem stopped.
I don't know the reason why. But anyway it seems usable
with this setting for the time being.

Jaakko, 
Please try this setting on your K3 too. 

TU & 73
Atsu, JE1TRV


----- Original Message ----- 
From: "Wayne Burdick" <n...@elecraft.com>
To: <je1...@a1club.net>
Cc: <elecraft@mailman.qth.net>
Sent: Wednesday, January 13, 2010 1:36 AM
Subject: Re: [Elecraft] K3 HI-TEMP ALARM


> We're looking into this.
> 
> 73,
> Wayne
> N6KR
> 
> On Jan 11, 2010, at 7:20 PM, je1...@a1club.net wrote:
> 
>> Hi folks!
>> Thank you for suggestions.
>>
>> In my previous post, I forgot to say that my K3 works without hi-temp
>> alarm after warming up (about 30min or so without transmit just  
>> receiving
>> status).
>>
>> So, it's just the same with Jaako's case.
>> My shack temp was around 15C these days.
>>
>> hmmm...
>>
>> Atsu, JE1TRV
>>
>>> Hi
>>>
>>> I have same problem, when shack temperature is below 17 degrees  
>>> Celcius
>>>
>>> When PA Temp is higher than 25 degrees C then power is OK.
>>>
>>> Jaakko OH1MA / K3 ser. 2952
>>>
>>>
>>> Hi Elecrafters!
>>>
>>> I have problem on my K3/100 (S/N3050, factory assembled).
>>> When I transmit more than 12W(means hi power amp on)
>>>  within about 30min after mains power on, HI-TEMP alarm
>>> occur and equipment is forced to set 5W.
>>>
>>> No problem at all when hi-power amp is through ( Po<12W ).
>>>
>>> Any idea?
>>> Thanks in advance
>>> 73, Atsu JE1TRV

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to