You say the power output stays the same.  Is this into a dummy load and
measured with a good RF watt meter (like Bird)?  If that is the case then
due to power staying the same,  the resistance the PA sees must be
decreasing.  Is this happening on all bands or just one or two? This could
be related to the LPF causing it if only one or two, need to check those
items in the LPF causing it.  If it is all bands, I would check the items on
the output side of T2 for correct value and soldering.
-- 
View this message in context: 
http://elecraft.365791.n2.nabble.com/K2-10W-PA-problem-tp5282243p5282647.html
Sent from the Elecraft mailing list archive at Nabble.com.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to