> Date: Tue, 2 Nov 2010 23:11:32 -0500
> From: [email protected]
> To: [email protected]
> Subject: [Emc-developers] possible bug in Axis calibration menu ?
>
> Before I make a formal bug report, I wonder if anyone else has seen this.
>
> In the Axis calibration menu, the entry for PID_MAX_VEL fails to show
> up on the FIRST axis only (axis 0). As far as I can tell, this parameter is
> correctly written in the .ini file, and also in the hal file that loads
> it to
> the PID pin. I have also had it reported to me that the same entry is
> missing in the tkemc calibration menu.
>
> Thanks,
>
> Jon
>
Jon if the setp command in your HAL file starts with a space calibration will
ignore it.
A sample of your INI and HAL file would help.
Chris M
------------------------------------------------------------------------------